ANSINSPIResidential Inground Swimming Pools-This standard is a revision of ANSI/NSPI-5 , Standard for Residential Inground Swimming. Standards such as ANSI/AHAM RAC, Room Air For homes with inground pools, ANSI/NSPI , Residential Inground Swimming. For the design, equipment, and installation of residential inground swimming pools. This standard is referenced in the International Codes. PURCHASE .

Author: Vill Gakazahn
Country: Ecuador
Language: English (Spanish)
Genre: Environment
Published (Last): 8 February 2004
Pages: 58
PDF File Size: 12.93 Mb
ePub File Size: 2.16 Mb
ISBN: 827-9-38218-936-8
Downloads: 71142
Price: Free* [*Free Regsitration Required]
Uploader: Kagagore

Maximum mesh size for chain link fences shall be a 2. We have no amendments or corrections for this standard.

Any outdoor swimming pool shall be completely enclosed by a barrier which shall not be more than fifteen feet 15′ from the edge of the walk areas as required by this chapter; and the combined measurement between the edge of said walk areas and said required barrier as measured at the farthest points of separation on each of the four 4 sides shall not exceed thirty two feet 32′ in total. The objective of this standard is to provide recommended minimum guidelines for the design, equipment, installation, and use of residential inground swimming pools.

All pool drain outlets shall be equipped with gratings having an area of openings not less than four 4 times the cross sectional area of the outlet pipe.

ANSI/NSPI – Residential Inground Swimming Pools

Such vacuum relief nzpi shall include at least one approved or engineered method of the type specified herein, as follows: If the makeup water is added directly to the pool, the outlet shall be at least six inches 6″ above the upper rim of the pool. Where a permanently installed pool is installed at a dwelling unit sat least one GFCI protected one hundred twenty five volt receptacle shall be located a minimum of ten feet 10′ 3.

If the pool width is more than thirty feet 30′ apart, multiple outlets shall be provided and spaced not more than thirty feet 30′ apart, nor closer than four feet 4′ to any wall. The answers to the above stated questions were given with the understanding that the said questions are to be considered individually and not collectively. Any disinfection method using materials other than chlorine compounds shall be subject to the approval of the building officer.

Pools shall snsi operated with due consideration to the comfort and well being of adjoining property owners. No type MC cable shall be permitted in conjunction with swimming pools. The energy requirements for portable spas shall be in accordance with Section Suction outlets shall be designed to produce circulation throughout the pool or spa. For the purpose of this section, the front line of any residence shall be a line drawn parallel to any road abutting the lot which intersects the point of the residence located closest to that road.

  GO PARC ERZIEHUNGSAUFTRAG PDF

ANSI/APSP Standards & Specifications, ANSI Standards List | APSP

Where provided, vacuum or pressure cleaner fitting s shall be located in an accessible position s at least six inches 6″ and not greater than twelve inches 12″ below the minimum operational water level or as an attachment to the skimmer s.

Already Subscribed to this document. The Petitioner is in the process of designing a 10, gallon residential swimming pool with a therapy spa in Bradenton, Florida, in accordance with the Florida Building Code. Said drawings and plans shall identify the side and rear yards of the property on which the swimming pool is proposed to be located as such yards are established by the village zoning ordinance.

The alarm shall sound continuously for a minimum of 30 seconds immediately after the door is opened and be capable of being heard throughout 200 house during normal household activities.

An approved gravity drainage system.

ANSI/APSP Standards & Specifications List

This definition includes inground, aboveground and onground swimming pools, hot tubs and spas. Where the top of the pool structure is above grade, such as a hot tub or spa, the barrier may be at ground level, such as the hot tub or spa, or mounted on top of the hot tub or spa. Standards Subsctiption may be the perfect solution.

Proceed to Checkout Continue Shopping. Please first log in with a verified email before subscribing to alerts. Drawings and plans first shall be presented to the building officer for examination and approval, and each pool shall be constructed in conformity with the approved plans.

Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is less than 45 inches 1, mmthe horizontal members shall be located on the swimming pool side of the barrier.

ANSI/NSPI-5 2003 Standard for Residential Inground Swimming Pools (PDF Download)

The flow and velocity limits in this standard are intended to prevent suction entrapment. The effective date is October 1, Pumps, filters, heaters, and other mechanical and electrical equipment shall be located outside of the pool enclosure. A pool cover which is placed over the water area, and is opened and closed with a motorized mechanism activated by a control switch.

The energy requirements for residential pools and inground spas shall be as specified in Sections Single or multiple pump circulation systems shall be provided with a minimum of two 2 suction outlets of the approved type. Section AG – Barrier Requirements: The system’s supply of recirculated water and makeup water to the pool shall be constructed snsi conformance with all the applicable provisions of this code.

Underwater lighting fixtures shall be approved for the service.

  IDRIES SHAH SUFIS PDF

The Petitioner is seeking clarification of the flow and velocity requirements for swimming pool piping contained in three standards referenced in the Florida Building Code: Swimming pool walls and floors shall be constructed of any impervious material which will provide a tight tank with white or light colored finish and easily cleaned surfaces. Notwithstanding the foregoing requirements of this section, a residence located on the same property as such an outdoor swimming pool may be used as one or more of the sides of the required enclosure.

If the makeup water supply line discharges to a surge or balancing tank, the point of discharge shall be at least six inches 6″ above the rim of the tank. The top of the barrier shall be at least 60 inches above grade measured on the side of the barrier which faces away from the swimming pool.

The petition is filed pursuant to, and must conform to the requirements of Rule No less than two 2 or more means of egress in the form of steps or ladders shall be provided for all swimming pools, one of which shall be located at the deep end of the pool ndpi one of which shall be located at the anei end of the pool. If the document is revised or amended, you will be notified by email.

D 1 is the point directly under the 203 of the diving boards. D 2 is the point at which the floor begins to slope upwards to the transition point. For the purposes of this combined or total measurement and the application of this section, any swimming pool shall be considered as having 4 sides, based upon the 4 most significant changes of direction. A anxi and lint catcher or strainer shall be installed on the suction side of the circulation pump to prevent hair, lint and other extraneous matter from reaching the pump and filters.

Section AG – Abbreviations: Any private swimming pool that is totally contained within a private structure and surrounded on all four 4 sides by walls of said structure. The maximum slope permitted between point D 2 and the transition point shall not exceed one unit vertical to three units horizontal 1: Pools shall be equipped with suitable facilities for adding makeup water as needed. All discharged water shall be drained entirely upon the property on which the swimming pool is located and shall not flow on any adjoining property.

Treads of steps and ladders shall be constructed of nonslip material and at least three inches 3″ wide for their full length.