Gardner Colour. The Gardner Colour scale as specified in ASTM D is a single number colour scale for grading light transmitting. Scale samples with colour. Designation: D – 98AMERICAN SOCIETY FOR TESTING AND MATERIALS Barr Harbor Dr., Reprinted from the Annual Book of ASTM Standards. Standard Test Method for Color of Transparent Liquids (Gardner Color Scale).

Author: Negul Mushicage
Country: Namibia
Language: English (Spanish)
Genre: Video
Published (Last): 9 May 2005
Pages: 332
PDF File Size: 5.31 Mb
ePub File Size: 7.77 Mb
ISBN: 933-2-92564-441-1
Downloads: 28566
Price: Free* [*Free Regsitration Required]
Uploader: Sazahn

A number in parentheses indicates the year of last reapproval. In any one set, no two standards shall be closer together than two thirds of the difference in x or y between corresponding reference standards. ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard.

We are a non-profit group that run this website to share documents. NOTE 2—The precision data were obtained using an instrument in which two standards are viewed simultaneously. If v1544 comparator is provided with a separate green filter in front of the light source, place this filter in the reference beam of the atsm beam spectrophotometer during calibration of each standard.

Size px x x x x Your comments are invited either for revision of this standard or for additional standards and d5144 be addressed to ASTM International Headquarters. We need your help!

ASTM D1544-04 (2010)

Some glass standards 1 This test method is under the jurisdiction of Committee D01 on Paint and Related Coatings, Materials, and Applications and is the direct responsibility of Subcommittee D The apparatus may be of any design, but should have the following characteristics: Precision and Bias 7. Users of this standard are expressly advised that determination of d154 validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility.

  IMPERIO INVISIBLE DANIEL ESTULIN PDF

There are other instruments available for color matching which would be expected to give similar results, but the statement above applies only to the instrument checked. Its application to other materials has not been tested.

Thank you for interesting in our services. No further reproductions authorized. If more precise measurements are needed, report as either matching a standard or lighter or darker. Please fill this form, we will try to respond as soon as possible.

Alternatively equip the spectrophotometer with a condensing lens to accomplish this purpose. NOTE 1—If desired, liquid standards matching the colors given in Table 1, in glass tubes similar to the sample tubes may be used. Current edition approved June 1, This standard has been approved for use by agencies of the Department of Defense.

Significance and Use 3. The color shall be produced by the glass components only. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. Please help us to share our service with your friends. We need your help to maintenance this website.

ASTM D – 04 Standard Test Method for Color of Transparent Liquids (Gardner Color Scale)

Viscosity tubes, as described in Test Method D, are satisfactory. Permission rights to photocopy the standard may also be secured from the ASTM website www.

  DRACULA RETOLD BY DIANE MOWAT PDF

Please copy and paste this embed script to where you want to embed Embed Script. The calibration of glass standards should be verified prior to use; a suitable procedure for their calibration is contained in Appendix X1. The specifications and approximate composition of these solutions are given in Aastm Method D — 58 T. Originally approved in No other units of measurement are included in this standard.

Last previous edition approved in as Atsm — It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. These may be filled with potassium chloroplatinate for the light colors and solutions of ferric chloride and cobalt chloride in hydrochloric acid for the darker colors.

If you xstm that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. If the material is perceptibly cloudy, first filter it. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn.